Indoor far-field darkroom

At present, it is the largest indoor far-field anechoic room in the field of mobile communication

The performance of the anechoic chamber in the early stage of construction, after strict simulation, the main reflection area adopts 1.6 meters high absorbing material; The Fresnel area adopts Chebyshev wave design to optimize the performance of the anechoic chamber. After the completion of the construction, after 203 rigorous testing, the performance test results are better than the design indicators; Compared with other testing sites in the same industry, it has more superior performance.

test quiet zone is large

the far-field anechoic chamber is the largest anechoic chamber in Asia at present. The larger the size of anechoic chamber, the larger the test static zone, the farther the receiving/sending distance, and the

High test efficiency

the efficiency of the dual-channel frequency sweep measurement system is improved by 8 times compared with the traditional dual-port frequency sweep measurement system. The system is equipped with two 8-port

Prevent misoperation

the system can create a “test scheme”, the scheme content contains frequency point, turntable rotation information, power amplifier, speaker selection, downward inclination and other information, can prevent operation errors, error

U turntable

compared with the traditional test turntable, the U-shaped test turntable has two test rotating surfaces, and the antenna test does not need the horizontal/vertical flip switch attitude. For MIMO antenna service beam testing, the horizontal beam

Performance indicators
  • darkroom size
  • frequency range
  • shielding effectiveness
  • quiet zone size
  • uniformity of field amplitude
  • static zone reflection level
  • polarization level difference
  • gain test stability
  • static zone cross polarization level
  • 75m * 40m * 40m
  • 500MHz-12GHz
  • >100dB (@0.5~12GHz)
  • 3.5m *3.5m *3.5m
  • ≤±0.25dB
  • 0.5~1GHz
  • ≤ -46.4dB  1.5~2.7GHz
  • ≤ -48.3dB  3~12GHz
  • ≤ -50.7dB
  • ≤ 0.25dB
  • <±0.15dB
  • <-40dB
Performance indicators
  • operating frequency range
  • maximum antenna diameter
  • maximum antenna weight
  • mechanical test accuracy
  • mechanical backlash
  • peak repeatability error
  • 0.5~12GHz
  • 3.5m
  • 300KG
  • ≦0.1°
  • <6'
  • ≤±0.2 dB

168 Near-field test system

one of the largest near-field test systems in the communication industry
The test static area is 3 meters, and the test turntable has high precision. The test system has high stability and small test deviation; It was verified by Theil Lab and Kyle.
Test system index
  • number of probes
  • probe Angle
  • system frequency
  • dynamic range
  • maximum subject size
  • mximum weight of measured object
  • probe array diameter (inside/outside)
  • darkroom size (L*W*H)
  • darkroom shielding efficiency
  • dark room quiet area
  • 167+1
  • 400MHz~6GHz
  • 45~70dB
  • 3m
  • 110kg
  • 7.0m/8.2m
  • 12m*10m*10m
  • >100dB
  • ≤3m

Satimo128 near-field test system

SATIMO latest Spherical 128 test system imported from France
The test static area is 3 meters, and the test turntable has high precision. The test system has high stability and small test deviation; It has been verified by Theil Laboratory and MVG system in France.
Test system index
  • number of probes
  • probe Angle
  • system frequency
  • dynamic range
  • maximum subject size
  • mximum weight of measured object
  • probe array diameter (inside/outside)
  • darkroom size (L*W*H)
  • darkroom shielding efficiency
  • dark room quiet area
  • 127+1
  • 2.571°
  • 400MHz~6GHz
  • 70dB
  • 4.16m
  • 200kg
  • 6.4m/7.66m
  • 12m*10m*10m
  • >100dB
  • ≤3m

Environmental reliability test equipment

Vibration testing machine
DC-3200-36
High and low
temperature humid heat test
DBWS11660
Rain test device
DLX-IPX4567
Drop testing machine
YT-DX1500
Salt spray test chamber
DDR1150
Universal material
testing machine
TD-503B
Complete set of
equipment for electrical
performance test
Power tolerance
test system
Zhongshan detection

Focus on testing communication antennas, including antenna radiation performance, electrical performance and environmental reliability; With 3 large …

0760-28167093

COPYRIGHT ZHONGSHAN QIANHENG TESTING CO., LTD

INDOOR FAR-FIELD DARKROOM

AT PRESENT, IT IS THE LARGEST INDOOR FAR-FIELD ANECHOIC ROOM IN THE FIELD OF MOBILE COMMUNICATION

TEST QUIET ZONE
IS LARGE

the far-field anechoic chamber is the largest anechoic chamber in Asia

HIGH
TEST EFFICIENCY

the efficiency of the dual-channel frequency sweep measurement system is

PREVENT
MISOPERATION

the system can create a “test scheme”, the scheme content contains

U
TURNTABLE

compared with the traditional test turntable, the U-shaped test turntable

PERFORMANCE INDICATORS

  • darkroom size
  • frequency range
  • shielding effectiveness
  • quiet zone size
  • uniformity of field amplitude
  • static zone reflection level
  • 75m * 40m * 40m
  • 500MHz-12GHz
  • >100dB (@0.5~12GHz)
  • 3.5m *3.5m *3.5m
  • ≤±0.25dB
  • 0.5~1GHz
  • ≤ -46.4dB 1.5~2.7GHz
  • ≤ -48.3dB 3~12GHz
  • ≤ -50.7dB
  • operating frequency range
  • maximum antenna diameter
  • maximum antenna weight
  • mechanical test accuracy
  • mechanical backlash
  • peak repeatability error
  • 0.5~12GHz
  • 3.5m
  • 300KG
  • ≦0.1°
  • <6′
  • ≤±0.2 dB

168 NEAR-FIELD TEST SYSTEM

one of the largest near-field test systems in the communication industry

the test static area is 3 meters, and the test turntable has high precision. the test system has high stability and small test deviation; it was verified by theil lab and kyle.
TEST SYSTEM INDEX
  • number of probes
  • probe Angle
  • system frequency
  • dynamic range
  • maximum subject size
  • mximum weight of measured object
  • probe array diameter (inside/outside)
  • darkroom size (L*W*H)
  • darkroom shielding efficiency
  • dark room quiet area
  • 167+1
  • 400MHz~6GHz
  • 45~70dB
  • 3m
  • 110kg
  • 7.0m/8.2m
  • 12m*10m*10m
  • >100dB
  • ≤3m

SATIMO128 NEAR-FIELD TEST SYSTEM

satimo latest spherical 128 test system imported from france

the test static area is 3 meters, and the test turntable has high precision. the test system has high stability and small test deviation; it has been verified by theil laboratory and mvg system in france.
TEST SYSTEM INDEX
  • number of probes
  • probe Angle
  • system frequency
  • dynamic range
  • maximum subject size
  • mximum weight of measured object
  • probe array diameter (inside/outside)
  • darkroom size (L*W*H)
  • darkroom shielding efficiency
  • dark room quiet area
  • 167+1
  • 400MHz~6GHz
  • 45~70dB
  • 3m
  • 110kg
  • 7.0m/8.2m
  • 12m*10m*10m
  • >100dB
  • ≤3m

ENVIRONMENTAL RELIABILITY TEST EQUIPMENT

VIBRATION TESTING MACHINE
DC-3200-36

HIGH AND LOWTEMPERATURE HUMID HEAT TEST
DBWS11660

RAIN TEST DEVICE
DLX-IPX4567

DROP TESTING MACHINE
YT-DX1500

SALT SPRAY TEST CHAMBER
DDR1150

UNIVERSAL MATERIAL TESTING MACHINE
TD-503B

COMPLETE SET OF EQUIPMENT FOR ELECTRICAL PERFORMANCE TEST

POWER TOLERANCE TEST SYSTEM

Zhongshan detection

Focus on testing communication antennas, including antenna radiation performance, electrical performance and environmental reliability; With 3 large …

400-775-001234

COPYRIGHT ZHONGSHAN QIANHENG TESTING CO., LTD